Aube-technologies TH147E-P Uživatelský manuál Strana 1

Procházejte online nebo si stáhněte Uživatelský manuál pro Kontrolní panel Aube-technologies TH147E-P. Aube Technologies TH147E-P User Manual Uživatelská příručka

  • Stažení
  • Přidat do mých příruček
  • Tisk
  • Strana
    / 4
  • Tabulka s obsahem
  • KNIHY
  • Hodnocené. / 5. Na základě hodnocení zákazníků
Zobrazit stránku 0
TH147E-P & TH148ELE-P 400-147-016-C 2008-01-08 1/4
The TH147E-P and TH148ELE-P thermostats can be used to control:
a forced air system - 2 or 3 wires
a hot water system with or without pump - 2 wires
a millivolt system - 2 wires
Note: The installation must be performed by an electrician.
2.1 Removing the Old Thermostat
IN ORDER TO AVOID ANY RISK OF ELECTRIC SHOCK, CUT
POWER TO THE HEATING SYSTEM.
n Remove the old thermostat to access the wires.
o Identify and label each wire (with the corresponding letter on the
wire terminal) and remove them from the terminals.
p If necessary, strip the end of each wire (maximum of 6 mm).
2.2 Installing the New Baseplate
Choose a location approximately 1.5 m above the floor and on
an inside wall. Avoid draughty areas (top of staircase, air outlet,
etc.), dead air spots (behind doors), direct sunlight or areas near
concealed pipes or chimneys.
n Remove the thermostat faceplate.
o Loosen the locking screw in order to separate the thermostat
from its baseplate (the screw cannot be completely removed).
p Gently tilt the thermostat upwards.
q Pass the wires through the opening of the baseplate and secure
the baseplate to the wall using the appropriate screws.
2.3 Terminal Designations
n
Introduction
1.
Features
TH147E-P
TH148ELE-P
Pump protection X X
Programmable cycle length X X
Battery replacement indicator X X
Backlit display X X
Programming:
- Preprogrammed schedule
- Temporary bypass
- Time display (12 h or 24 h)
X
X
X
X
X
X
X
X
Interchangeable faceplates X X
Unoccupied mode activated remotely X
Automatic daylight savings changeover X
Display
Adjustment
buttons
Backlight
button
Comfort
temperature
preset
Mode selection /
program exit
Program
button
Economy
temperature
preset
Temperature
Schedule
Time
Manual mode
Heating is On
: Comfort temperature indicator
: Economy temperature indicator
Day
Display
Appears when the
setpoint temperature
is displayed
Low battery indicator
Automatic mode
Unoccupied mode
o
Installation
2.
R Power
W Load
Un / Un Unoccupied mode input (TH148ELE-P only)
TH147E-P & TH148ELE-P
Installation and User Guide
Programmable Thermostats
400-147-016-C (TH147_148 P Europe) ENG.fm Page 1 Tuesday, January 8, 2008 2:47 PM
Zobrazit stránku 0
1 2 3 4

Shrnutí obsahu

Strany 1 - TH147E-P & TH148ELE-P

TH147E-P & TH148ELE-P 400-147-016-C 2008-01-08 1/4The TH147E-P and TH148ELE-P thermostats can be used

Strany 2 - Basic Functions

TH147E-P & TH148ELE-P 400-147-016-C 2008-01-08 2/42.4 Connecting the Heating System2.5 Unoccupied Mode

Strany 3 - Programming

TH147E-P & TH148ELE-P 400-147-016-C 2008-01-08 3/43.5 Control Mode3.5.1 ManualUse this mode to set the

Strany 4 - Technical Assistance

TH147E-P & TH148ELE-P 400-147-016-C 2008-01-08 4/4n Press the backlight button until the configuration

Příbuzné modely TH148ELE-P

Komentáře k této Příručce

Žádné komentáře